Page view 12
12
display Setting
Setting
range
Pre-
setting device
Decimal places Sensor 1
number of decimal places for sensor 1 shown in the
display
0..0.000 0.0 For all devices
Lower display range (Low Range) Sensor 1
Lower display range limit
-999..9899 0.0 For all devices
Upper display range (High Range) Sensor 1
Upper display limit
-899..9999 10.0 For all devices
LED – light indicator Sensor 1
ON
OFF
On
Off
On For all devices
Sensor 2 input mode of signal
Sensor 2, input 0..5V
Sensor 2, input 0..10V
Sensor 2, input 4..20mA, source
Sensor 2, input 4..20mA, drain
5V
10V
mA.r.
mA.S.
10V HDA 5500 - 1 - X - XX - XXX
Decimal places Sensor 2
number of decimal places for sensor 1 shown in the
display
0..0.000 0.0 HDA 5500 - 1 - X - XX - XXX
HDA 5500 - 3 - X - XX - XXX
Lower display range (Low Range) Sensor 2
Lower display range limit
-999..9899 0.0 HDA 5500 - 1 - X - XX - XXX
HDA 5500 - 3 - X - XX - XXX
Upper display range (High Range) Sensor 2
Upper display limit
-899..9999 10.0 HDA 5500 - 1 - X - XX - XXX
HDA 5500 - 3 - X - XX - XXX
LED – light indicator Sensor 2
ON
OFF
On
Off
On HDA 5500 - 1 - X - XX - XXX
HDA 5500 - 3 - X - XX - XXX
Sensor 3 input mode of signal
Sensor 3, input 0..5V
Sensor 3, input 0..10V
Sensor 3, input 4..20mA, source
Sensor 3, input 4..20mA, drain
5V
10V
mA.r.
mA.S.
10V HDA 5500 - 1 - X - XX - XXX
Decimal places Sensor 2
number of decimal places for sensor 1 shown in the
display
0..0.000 0.0 HDA 5500 - 1 - X - XX - XXX