1
3.2.1 Pin connection
Supply voltage connector X1
X1
device PIN description Variante
HDA 5500 – X – X – AC – 000
~ / ~
Supply voltage 85VAC bis 265VAC 50/60Hz 1 , 2 and 3
HDA 5500 – X – X – DC – 000 + / - Supply voltage 24VDC 1 , 2 and 3
Signal connector X2
X2
device 12 3 4567891011 Variante
HDA 5500 – 0 – X – XX – 000 RXD TXD DGND
Analog
Output
AGND +12V
Sensor 1
Input
1 , 2 and 3
HDA 5500 – 1 – X – XX – 000 RXD TXD DGND
Analog
Output
AGND +12V
Sensor 1
Input
Sensor 2
Input
Sensor 3
Input
AGND 1 , 2 and 3
HDA 5500 – 2 – X – XX – 000 RXD TXD DGND
Analog
Output
AGND +12V
Sensor 1
Input
Freq Start Stop Clear 1 , 2 and 3
HDA 5500 – 3 – X – XX – 000 RXD TXD DGND
Analog
Output
AGND +12V
Sensor 1
Input
Pt100 Pt100 Pt100 Pt100 1 , 2 and 3
Connection of the relais
contacts X3 / X4
X3 X4
device 12 3 456123456Variante
HDA 5500 – X – 0 – XX – 000 1
HDA 5500 – X – 1 – XX – 000
R1
N/C
R1
Base
R1
N/O
R2
N/C
R2
Base
R2
N/O
2
HDA 5500 – X – 2 – XX – 000
R1
N/C
R1
Base
R1
N/O
R2
N/C
R2
Base
R2
N/O
R3
N/C
R3
Base
R3
N/O
R4
N/C
R4
Base
R4
N/O
3
Page view 1