16. Application examples
16.1 HYDRAULIC POWER UNIT: TO MONITOR MINIMUM FLUID LEVEL
WITH ADVANCE WARNING AND ALARM
In this example application, an advance warning should be given when the fluid
level reaches 1.18 inch and tank refilling should be started. An alarm should be
triggered if the fluid level drops below 0.39 inch and reset once the fluid level
has reached 0.59 inch again.
To achieve this as described in the example, the following settings must be
made in the ENS 3000 menu and the two switching points must be set as
follows:
Menu item Selection Numerical value
Switching output S.S.1 assignment Niv [= fluid level]
Switching mode S.m. 1 SP
Switching direction S.d. 1 off
Switch-on delay T
on
1 0
Switch-off delay T
off
1 0
Switching output S.S.2 assignment niv
Switching mode S.m. 2 SP
Switching direction S.d. 2 on
Switch-on delay T
on
2 0
Switch-off delay T
off
2 0
Switching point settings Numerical value
Switching output S.P.1 1.2
Hysteresis switching output Hi.1 0.02
Switching output S.P.2 0.59
Hysteresis switching output Hi.2 0.2