Hydac CMU 1000 User Manual Page 101

  • Download
  • Add to my manuals
  • Print
  • Page
    / 122
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 100
Condition Monitoring Unit CMU 1000 Page 101
Revised 17.12.2009 HYDAC ELECTRONIC GMBH Mat.-No.: 669749
7.7.4 Or
The Or function links the two Boolean inputs with the "or" operation
and supplies the result to its Boolean output.
The output is "1" if one of the two inputs is "1". If both are "0", then
the output will also be "0".
The following log table makes this function clear.
x
1
x
2
y
0 0 0
0 1 1
1 0 1
1 1 1
Inputs: x
1
: (Boolean)
x
2
: (Boolean)
Outputs: y: (Boolean)
Parameters: -
7.7.5 Not - Or
The Not - Or function links the two Boolean inputs with the "nor"
operation and supplies the result to its Boolean output.
The output is "0" if one of the two inputs is "1". If both of the inputs
are "0", then the output will be "1".
The following log table makes this function clear.
x
1
x
2
y
0 0 1
0 1 0
1 0 0
1 1 0
Inputs: x
1
: (Boolean)
x
2
: (Boolean)
Outputs: y: (Boolean)
Parameters: -